Yebis Engineering PLC Logo
PLC · Addis Ababa · Ethiopia
Start a Project
SEC_ELE-03 // ELECTROMECHANICAL & MEP // DIVISION 03
STANDARD: IEC 60364 / EEPSTATUS: FIELD CERTIFIED
DIVISION 03ELECTROMECHANICAL & MEP // HIGH & LOW VOLTAGE

Uninterrupted Power Architecture. Engineered for Grid Resilience.

Turnkey building electrical distribution, transformer substations, automated transfer switch (ATS) synchronization, and clean backup power infrastructure for commercial complexes, healthcare facilities, and residential towers.

Ethiopian electrical conditions demand architectural-grade electrical engineering. We eliminate voltage spikes, phase imbalances, and blackout downtime through precision switchgear fabrication, balanced load distribution, and fail-safe generator synchronization plants designed specifically for high-occupancy buildings across Addis Ababa and regional centers.

+
+
SPEC_CARD // ELE-03BUSBAR CONTINUITY: 100% VERIFIED
Industrial Electrical Distribution Panel and Switchgear Installation
MAIN DISTRIBUTION PANEL (MDB) // 400V 50HZFORM 4B
ISOLATION CLASS: FORM 4B
BREAKER SPEC: 4P ACB MOTORIZED
FAILOVER TIME: < 8 SECONDS
STANDBY GEN: ATS SYNCHRONIZED
ELECTRICAL SPECIFICATIONS // MEP PERFORMANCE TELEMETRY
Voltage Transformation
11kV / 400V

Compact substation transformers and cast-resin distribution packages.

Emergency Failover
< 8.0 SEC

Automated generator synchronization with motorized ATS transfer.

Power Quality (THD)
< 3%

Harmonic filtering protecting elevators, pumps, and sensitive electronics.

Earthing Resistance
< 1.0 Ω

Chemical earth pits engineered for Addis Ababa's volcanic basalt substrata.

Regulatory Code
IEC / EEP

Full compliance with IEC 60364 and Ethiopian Electric Power statutory standards.

FOUR-PILLAR MEP ARCHITECTURE

Electromechanical Deliverables

STANDARDS: IEC 60364 // BS 7671 // EEP REGULATORY COMPLIANCE
SUB-SCOPE 01 // POWER DISTRIBUTIONFORM 4B CERTIFIED

Main Distribution Boards (MDB) & SDB Networks

Custom-built, modular distribution panels engineered for commercial buildings, healthcare suites, and multi-tenant complexes. Internal segregation isolates individual circuits for safe maintenance without total facility shutdown.

TECHNICAL SCOPE:
Main Distribution Boards (MDB) up to 4000A
Sub-Distribution Boards (SDB) per floor zone
Busbar trunking risers for vertical high-rises
Digital multi-function power monitoring meters
SUB-SCOPE 02 // EMERGENCY STANDBYN+1 REDUNDANCY

Backup Generators & Synchronized ATS

Uninterrupted backup power architecture designed for high-volatility grid environments. We size and install heavy-duty diesel generators with sound-attenuated enclosures, fuel transfer systems, and motorized ATS panels.

TECHNICAL SCOPE:
Synchronized multi-generator plant setups
Motorized Automatic Transfer Switches (ATS)
Dedicated underground bulk fuel storage skids
Critical emergency circuit isolation panels
SUB-SCOPE 03 // EXTRA LOW VOLTAGE (ELV)CAT 6A / FIBER BACKBONE

Structured Cabling & Building Systems

Complete low-current infrastructure integrating enterprise data networks, access control, surveillance, and automated addressable fire alarm systems seamlessly within the building fabric.

TECHNICAL SCOPE:
Structured Cat6A / OM4 fiber optic cabling
Addressable smoke detection & fire alarm systems
CCTV surveillance & IP access control portals
Energy-efficient LED lighting control automation
SUB-SCOPE 04 // PROTECTION & EARTHINGZONE IV SURGE PROTECTION

Earthing & Lightning Protection Grids

High-integrity earthing grids and rooftop Faraday cage air terminals engineered to protect buildings from severe tropical lightning strikes and grid-level electrical surges common across the Ethiopian highlands.

TECHNICAL SCOPE:
Rooftop copper air terminal lightning networks
Chemical earth wells (< 1.0 Ohm verified)
Type 1 + 2 surge protection devices (SPD)
Equipotential bonding across all metallic services

5-Phase MEP Quality & Commissioning Protocol

ZERO FAULT TOLERANCE // FULL CONTINUITY VERIFIED
01PHASE 01

Electrical Load Calculation & System Sizing

Rigorous maximum demand analysis, diversity factor calculation, and cable sizing according to architectural floor layouts and equipment rosters.

GATE: LOAD AUDIT & UTILITY APPROVAL
02PHASE 02

Containment & Conduit Rough-In

Installation of heavy-duty galvanized steel cable ladders, cable trays, and cast-in slab conduits before screeding and drywall closing.

GATE: PRE-POUR CONDUIT INSPECTION
03PHASE 03

Cable Pulling, Trunking & Substation Erection

Low-smoke zero-halogen (LSZH) cable pulling, transformer rigging, and switchboard positioning on vibration-isolated concrete plinths.

GATE: CONTINUITY & MEGGER CLEARANCE
04PHASE 04

Panel Termination, ATS & Generator Integration

Laser-calibrated torque terminations, ATS motorized link installation, generator exhaust ducting, and emergency battery charger setup.

GATE: COLD COMMISSIONING AUDIT
05PHASE 05

Live Energization, Load Balancing & Certification

Coordinated utility cutover with Ethiopian Electric Utility (EEU), 3-phase load balance testing, infrared thermographic camera scan, and as-built single line diagrams (SLD).

GATE: FINAL ENERGIZATION & STATUTORY PERMIT
ELECTRICAL TESTING BENCHMARK

Quality Assurance & Commissioning Matrix

IEC 60364 // BS 7671 // IEEE 81 // NFPA 110
System Sub-ScopeEngineering BaselineField Verification ProtocolCompliance CodeStatus
Main Switchgear Insulation (Phase-to-Earth)> 100 Megohms @ 1000V DCDigital Megger Insulation Resistance SurveyIEC 60364-6 / EEPCERTIFIED PASS
Emergency Power Cutover & ATS Transfer< 8.0 Seconds Full RecoverySimulated Mains Blackout Failover TestNFPA 110 / ISO 8528VERIFIED (< 7.2S)
Basalt Substrata Earthing Resistance< 1.0 Ohm True Earth4-Point Fall-of-Potential Earth TestingIEEE 81 / BS 7430OPTIMIZED (0.78 Ω)
Switchboard Busbar Thermal GradientDelta-T < 15°C Under Full LoadCalibrated FLIR Infrared Thermal Camera ScanNETA ATS / IEC 61439HOT-SPOT FREE
Life Safety & Emergency Light Illumination> 10.8 Lux along Exit CorridorsOptical Photometer Lux Level MappingEBCS / BS 5266COMPLIANT PASS
DIVISION 03 // MEP TECHNICAL INTAKE

Equipping a Commercial, Healthcare or Residential Development with MEP?

Send us your single line diagrams (SLD), electrical load schedules, or tender drawings. Our electrical engineering team provides comprehensive bill of quantities (BOQ) review and substation sizing for projects across Ethiopia.

HEADQUARTERS: BOLE ROAD, ADDIS ABABA|PHONE: +251 91 151 7784|STATUS: GRADE 1 CERTIFIED